ªÅ½Õ¤è¦¡·§½× ¤T. ªÅ½Õ¤è¦¡ 1.««ª½¼h¬y¡G²M¹ÒªÅ®ð¦Û«Î³»¦Ü¦aªOªº¬y³q¤è¦¡¡C ÀuÂI | ¯ÊÂI | - ®ÄªG§¹¥þ¡C
- ¤£©ö¬°§@·~¤Hû¤Î¤u§@ª¬ºA©Ò¼vÅT¡C
- ¶}©l¹BÂà«á§Y¨è«K¦¨Ã©wª¬ºA¡C
- ¯»¹Ðªº°ï¿n¤Î¦AÄƯB·¥¤Ö¡C
- ºÞ²z®e©ö¡C
| - ¶·ª`·N¤ÑªáªOªºµL®ÄªÅ¶¡¦p·Ó©úµ¥¡]¨¾¤î¶Ã¬y¡^¡C
- ´«¹LÂo¾¹¸û³Â·Ð¡C
- ³]³Æ¶O¥Î«Dªk°ª¡C
- ¹j¶¡ªºÂX¥R¤ñ¸û§xÃø¡C
|
2. ¤ô¥¼h¬y¡G²M²bªÅ®ð¥Ñ¤ÑªáªO80%¥H¤W§j¥X¡A¾ÀªO40%¥H¤W§l¤J¡A¤ÑªáªO¥ç¥i¡C ÀuÂI | ¯ÊÂI | - ¶}©l¹BÂà«á§Y¨è«K¦¨Ã©wª¬ºA¡C
- ºc³y²³æ
| - ¤W´åªº¼vÅT·|¦b¤U´å¥X²{¡C
- ¤Hû¤Î¾÷¾¹ªº°t¸m¤ÎºÞ²z¶·ª`·N¡C
- ³]³Æ¶O¥Î«D±`°ª¡C
- ¹j¶¡ªºÂX¥R¤ñ¸û§xÃø¡C
|
3. ¶Ã¬y¡G²M²bªÅ®ð¹LÂo¾¹§j¥X¤f¡A¥Ñ¦aªOªþªñ§l¤J¡CClass 10,000~100,000¾A¥Î ÀuÂI | ¯ÊÂI | - ºc³y²³æ¡C
- ³]³Æ¶O¥Î§C¡C
- ¹j¶¡ªºÂX¥R¤ñ¸û®e©ö¡C
- Y¦A¥[¥ÎµL¹Ð¥x«h¥i½T«O°ª¼ä²b«×¡C
| - ¥Ñ©ó®ð¬yªº¶Ã¬y¦Ã¬V²É¤l¡A¦³¥i¯à¦b«Ç¤º´`Àô¡C
- ¤Hû¤Î¾÷¾¹ªº°t¸m¤ÎºÞ²z¶·ª`·N¡C
- ¨ìéwª¬ºA¶·n¤@¬q®É¶¡¡C
|
²Õ¦X«¬µL¹Ð«ÇªÅ½Õ½c - «ö¸Ë¬I¤u®e©ö¡AÁYµu¤u´Á¡A¦b¯U¯¶ªº³õ©Ò¤]¥i¥H«ö¸Ë¡B²¾¸Ë¤]«D±`®e©ö¡C
- ±Ä¥ÎPU¹j¼ö¡A¨ã¦³¨ô¶VªºÂ_¼ö©Ê¡B¨¾¤ô©Ê¡B¨¾¤î¤ô¯]ªº¾®µ²¡C
- §Ö¤â¹_µ²¦X¤è¦¡¡A½T«O°ª«×ªº±K³¬©Ê¯à¡A±µ¦X³Bµ´¤£·|¦³º|®ð²{¶H¡A¨ã¦³Àu²§ªº±j«×¡A@¤[¤Î@À£©Ê¡C
- ¨ô¶VªºÂ_¼ö®ÄªG¡A±N«O§N¤uµ{¤@¨Ö²Î¦X¡A°ª«×±K³¬©Ê»P¶Ç²Î«O·Å¤è¦¡¬Û¸û¤§¤U¡A¤j¤jªº´£°ªªÅ½Õ¾÷ªº¹BÂà®Ä²v¡A¸`¬Ù¯à·½¡AÁYµu¤u´Á¡A°§C¦¨¥»¡C
- ¥iµø¤uµ{ªÅ½Õ¯à¤O³]p½d³ò»s§@¡A³W®æ¥i¤j¥i¤p¡A¥i¨Ì²{³õ¦a§Î³]p¡B»s³y¡B«ö¸Ë¬I¤u¡C
HEAP FILTER CASING °ª®Ä²v¹LÂo½c---¥»Åé¡G¯Nº£¿ûªO §j¥X¤f¡G¤£ù׿û¨R¤Õºô Åé¿n¤p¡A¤£¥eªÅ¶¡¡A¸Ë¸m¦bµL¹Ð«Ç¤ºªºªÅ®ð¥X¤f³B¡A±N²M²bªÅ®ð°e¤JµL¹Ð«Ç¤º¡A¨Ã±N¸¨¹Ð¶q®ø°£¨ì99.99%¥H¤W¡A¨ÏªÅ®ð¤º¹F¨ì°ªµL¹ÐªºÀô¹Ò¡C Smaill size occupying little space. Installed at the airoutlet of the clean room to send clean air into the clean room and remove at least 99.99%dust to create a highly dust-free environment.
³W®æ | 1340mm¡Ñ740mm¡Ñ400mm | ®r¤J¤Ø¤o | 1311mm¡Ñ711mm | ¶i·¤f | ¾ò¶ê§Î©Î¶ê¤Õ§Î | ¤£ù׿û¨R¤Õºô¥~³ò | 1340mm¡Ñ740mm | ³W®æ | 740mm¡Ñ740mm¡Ñ740mm | ®r¤J¤Ø¤o | 711mm¡Ñ711mm | ¶i·¤f | ¾ò¶ê§Î©Î¶ê¤Õ§Î | ¤£ù׿û¨R¤Õºô¥~³ò | 740mm¡Ñ740mm |
ª¼ªO µL¹Ð®wªO §÷½èºØÃþ¡G¨¾¤õPU´OªO¡B¨¾¤õ¯È¸Á±_ªO¡B·Ç¤£¿U¾T¸Á±_ªO¡BPU´OªO ¦aªOºØÃþ¡G°ª¬[¦aªO¡B¾É¹q¦aªO¡BÀô®ñ¾ð¯× À³¥Î¹ê¨Ò ¡]AIR SHOWER¡^ªÅ®ð¯D¹Ð«Ç µL¹Ð«Çªº¥²»Ý³]³Æ¡A³]¦b¡]CLEAN ROOM¡^¤J¤f³B¡A¹ï¶i¤J«Ç¤ºªº¤H»Pª««~¡A¥H°ª³t¼Q®ð¦¡²M²bªÅ®ð§j©Ø¡A±N¤HÅé¦çªA¡Bª««~¤WªþµÛªº¦Ç¹Ð©M²Óµßµ¥²M°®²b«á¤~¯à¶i¤J¡C
The equipment required for the clean rooms is placed at the entrance of the clean room. They would spray clean air at a high speed to blow off the dust and bacteria attached to the clothes and articles of the people entering the clean room.
¤H»Pª«¨â¥Î¦¡AIRSHOWERµL©³®y¦¡³]p¡A¥H«K©ó±À¨®ªº¶i¥X¡A¨Ã¥i©óAIRSHOWER¤º³¡¦aªO¥¾QSUS304¤£ù׿ûªO¹Ù©Î«O¯d쥻¤§EPOXY¦aªO¡C
The no-base design of the dual-purpose air shower¡]for people and article¡^is conven for the movement of the carts. SUS304 stainless steel plates can be paved flatly no the floor of the air shower, or the original epoxy floor can be reserved. §÷½è»¡©ú | ¤º¥~´ß«þº£¿ûªO¡A¤º©³¤£ù׿û | ·³t | ¬ù26m/s | ·¶q | 17~20cmm. | °ª®Ä²v¹LÂoºô | 0.3£gm²É¤l®É99.99% | ¼Q¼L | 16Ó¡]ABS®I¤J¦¡¡^ | ·Ó©ú | 20W¡Ñ1 ¡® 40W¡Ñ1 | ·¨® | 1/2HP 2P¡Ñ1¡A2P/4P¡Ñ1 | ¹q·½ | ¤T¬Û380V & ¤T¬Û220V, 60Hz |
«¬¸¹ \ ¤Ø¤o | W | D | H | ¨C¦¸¨Ï¥Î¤H¼Æ | AS-131080 | 1300 | 1000 | 2140 | 1 | AS-131280 | 1300 | 1200 | 2140 | 2 | AS-131580 | 1300 | 1500 | 2140 | 3 | AS-132080 | 1300 | 2000 | 2140 | 4 | ³q¹D¤Ø¤o | 800m/m | D-100m/m | 2000m/m | | AS-141090 | 1400 | 1000 | 2140 | 1 | AS-141290 | 1400 | 1200 | 2140 | 2 | AS-141590 | 1400 | 1500 | 2140 | 3 | AS-142090 | 1400 | 2000 | 2140 | 4 | ³q¹D¤Ø¤o | 900m/m | D-100m/m | 2000m/m | |
SHOWER & CURTAINED PASS BOX ¯D¹Ð/¼ä²b¶Ç»¼½c ¯SÂI¡G - ¤u§@°Ï¤º±±Ä¤£ù׿ûªO¡A¥¾ã¥ú¼ä¡C
- ¶Ç»¼µ¡¨âÃäªù±Ä¥ÎÁn¥ú±±¨î¡A´£¿ô±z¨âªù¤£¯à¦P®É³B©ó¶}±Òª¬ºA¡C
- ¶Ç»¼µ¡¨âªùÁÙ¥i°t¥H¹q¤lÁpÂê¥\¯à¡A½Ð±z¦bq³f®Éµù©ú¡C
Features¡G - A stainless steel plate is adopted for the floor inside the working zone. it is smooth, bright and clean.
- The doors at both sides the delivery window are controlled by sound and light to remind you that both doors can not be opened at the same time.
- The both doors of the delivery window can be equipped with an electronic interlock device. If necessary, please indicate your orders.
«¬¸¹ \ ¤Ø¤o | W¡ÑD¡ÑH | ¤u§@°Ï¤Ø¤o W¡ÑD¡ÑH | PBS-787 | 900mm¡Ñ800mm¡Ñ1750mm | 700mm¡Ñ700mm¡Ñ700mm | PBS-887 | 1000mm¡Ñ800mm¡Ñ1750mm | 800mm¡Ñ700mm¡Ñ700mm | PBS-987 | 1100mm¡Ñ800mm¡Ñ1750mm | 900mm¡Ñ700mm¡Ñ700mm |
¡@ °e·°¨¹F | HEPA | 1/2HPI£r220V | 24"¡Ñ24"¡Ñ3" | 1/2HPI£r220V | 24"¡Ñ24"¡Ñ3" | 1/2HPI£r220V | 24"¡Ñ24"¡Ñ3" |
Pass Box¶Ç»¼½c ¶Ç»¼µL¹Ð«Ç¤º»P¥~¤§ª««~¡A¥H¨¾µL¹Ð«Ç¤º¤§¦Ã¬V¡A¤À«Ç¤º¡B«Ç¥~Âù±ªù¡A¤º³¡©M¥~³¡ªù¡A¤£¯à¦P®É¶}±Ò¡A¥i¸Ë±N²£«~ªº¶i¥X²¾°Ê±±¨î¦b³Ì¤pªº½d³ò¥H¨¾¤î¦Ç¹Ð¡B²Óµßªºº¯¤J»P²£¥Í¡C ¯SÂI¡G ±Ä¥Î³sÂêÂùªù±±¨î¤§¶Ç®Æ½c¡A¥i¦³®Ä´î¤Ö¤Hû¶i¥X¤§ÀWÁc¡AÁקK«Ç¤º¥~ªÅ®ð¤§¦Ã¬V¡C
¥\¯à¡G ¤º¥~ªù³sÂê¡B¾÷±ñ³sÂê¡B³q¸Ü¾¹¡B¸Á»ï«ü¥Ü¾¹¡B«ü¥Ü¿O¡C¡]¥H¤W³W®æ¥i¥[¸Ë±þµß¿O¡^ ¤£³W®æ¶Ç®Æ½c¥i¨Ì«È¤á»Ýn³]p¡B»s³y
«¬¸¹ | W | H | D | PB-555 | 700 | 600 | 600 | ³q¹D¤f | 500 | 500 | 500 | PB-666 | 800 | 700 | 700 | ³q¹D¤f | 600 | 600 | 600 | PB-777 | 900 | 800 | 800 | ³q¹D¤f | 700 | 700 | 700 | PB-888 | 1000 | 900 | 900 | ³q¹D¤f | 800 | 800 | 800 |
SAFETY DAMPER ªÅ½Õ¬ªÀ£»Ö ·§z¡G ¸Ó¸Ë¸m¥i¼sªx¥Î©ó²b¤Æ¨®¶¡©Î¼ä²b«Ç¡A¥Î¨Óºû«ù«Ç¤º»P«Ç¥~ªº¥¿À£®t¡A¨Ï«Ç¤º¦h¾lªÅ®ð±Æ¥X¡Aªý¤î«Ç¥~ªÅ®ð«I¤J¡C ¯SÂI¡G
- ¦w¸Ë«¬¦¡¬°¾À±¾¦¡¡AÀð¾À«p«×¦b30~50mm ¤º¡A¥i»{·N½Õ¾ã¡]¸`¡^¡C
- ¦a²z¦ì¸m¥i®Ú¾Ú·¶q¡BÀ£®tn¨D¶i¦æ½Õ¾ã¡]¸`¡^¡C
Brief Introduction This device can be widely used in the purifying shop or the clean room to maintain the indoor and outdoor positive pressure difference. It helps exhaust the excessive air from the room and prevent the outdoor air from entering the room. Features¡G - The wall type device has a thickness of 30~50mm which at will.
- The position of the heavy ram can be adjusted according to air flow and pressure difference.
«¬¸¹ | SD600 | °_©lÀ£®t | 0.5mmAq | ¨Ï¥ÎÀ£®t½d³ò | 0.5~2.5 mmAq | ·¶q | 0~1500m3/h | ¦w¸Ë¶}¤f¤Ø¤o | 560W¡Ñ360H mm |
¡]Dust-Free & Germ-Free Lighting Device¡^µL¹ÐµLµß«Ç¤é¥ú¿O¨ã ©T©w¤è¦¡¡G§l³»¦¡¡]Ceiling Sucting Type¡^ ³W®æ | ³W®æ | ¿OºÞ¼Æ¶q | R-402 | 1170mm¡Ñ570mm¡Ñ110mm | 40w¡Ñ2 , 4¡Ñ2 | 40w¡Ñ3 , 4¡Ñ3 | R-20W | 620mm¡Ñ310mm¡Ñ110mm | 20w¡Ñ2 , 2¡Ñ2 | 20w¡Ñ3 , 2¡Ñ3 |
©T©w¤è¦¡¡G´O¤J¦¡¡]Inserting Type¡^ ³W®æ | ³W®æ | ¿OºÞ¼Æ¶q | L-40W | ´O¤J¥~³ò¤Ø¤o1310mm¡Ñ345mm¡Ñ130mm ´O¤J¤Õ¤Ø¤o1265mm¡Ñ300mm | ÂùºÞ / ³æºÞ |
FFU-FAM FILTER UNIT ¶°¹Ð¹LÂo¾¹ ¯SÂI¡G´õ½ü¦¡¯S®í³]p¤§¾É¬y·¹D¡C¤Þ¾É®ð¬y¥§¡³q¹LFILTER¡C Features¡G The wind channel with special turbine design may guide air flow to pass through the filter evenly¡C
·³t¡B·¶q»P¾¸µÃö«YÈ | °¨¹FSection | 1 | 2 | 3 | ·³tm/sec | 0.35 | 0.45 | 0.60 | ·¶qCMM | 14 | 15 | 22 | ¾¸µdb | 48 | 50 | 55 |
¡@ ªì¯Å¹LÂoºô | NYLON¹LÂoºô¡]470¡Ñ340¡^1PCS | °ª®Ä¹LÂoºô | ¤Ø¤o | 570¡Ñ1170¡Ñ70 | HEPA | 0.3£gm¡Ö99.99% | °¨¹F¤Î·®° | 110Wlmperller | µ²ºc§÷½è | SUS¡304.8mm«p | ¹q·½ | AC/60Hz 1£r OR 3£r 220V |
CLEAN BENCH ²¾°Ê¦¡µL¹Ð¤u§@Âi ---³W®æ: 1400¡Ñ700¡Ñ1950 CLEAN BENCH µL¹Ð§@·~Âi «¬¦¡ | WLB18V08 | ±µÄò¹Ï | TFA407851 | ²M²b«× | µ¥¯Å100¡]0.5£gm¡^ | §j¥X·³t | 0.5m/s | ¶°¹Ð²v | 0.3£gm99.97%¥H¤W | ¹q·½ | 3£r¡A200V¡A60Hz | °e·¾÷ | FFU2¥x1£r¡A220V | ·Ó©ú¿O | 40W 3¤ä ¥Õ¦â | ´¡ÀY | 1£r¡A100V¡AE¥I¡A3Ó | ¥»Åé | ¿ûªO«þº£ | HEPAÂo¹Lºô | 610H¡Ñ760W¡Ñ150D 2ªT ¦h·¶q | Pre Âo¹Lºô | ¥§Às¤£Â´¥¬ | ¥~«¬¤Ø¤o | 1800W¡Ñ800D¡Ñ1950H |
STANDARD TYPE CLEAN BENCH ¼Ð·Ç«¬¼ä²b¤u§@Âi ³o¬O¤@ºØ³q¥Î©Ê¸û±jªº§½³¡²b¤Æ¤u§@Âi¡A¥¦¼sªx¾A¥Î©ó¹q¤l¡B°ê¨¾¡Bºë±K»ö¾¹!¡B»öªí¡B¨îÃĵ¥¦æ·~¡C - ««ª½¬y§Î¡A¶}©ñ¦¡Âi±¡A¾Þ§@¤è«K¡C
- °t³ÆÀ£®tªí¡A¥iÀH®É´x±±°ª®Ä²v¹LÂo¾¹¡A²Õ¤OÅܤƱ¡ªp¡C
- ±Ä¥Î¥i½Õ¶q·¾÷¨t²Î¡A«OÃÒ¤u§@°Ï·³t©l²×©ó²z·Qª¬ºA¡C
µ²ºc | ÅKªO¯Nº£ | ¤u§@Âi± | SUS¡304§÷½è | §¨®Ç´OªO | 5mm«p¤§¬Á¼þ | ²M¼ä«× | ¥H·L¹Ð´ú¸Õ¾¹´ú¸Õ¡A0.5£g¤§¹Ð²É½d³ò¦b¨C¥ß¤è^§`¤£¶W¹L100Ó¡A100¯Å¤§¼Ð·Ç¡C | HEPA®Ä²v | ¥HD.O.P ´ú¸Õ¡A¥h°£0.3£gm¥H¤W¤§¹Ð²É¡A®Ä²v°ª¹F99.9%¥i¨Ñ¿ï¾Ü¡C | ¹wÂoºô | ¬Á¼þÅÖºû§÷½è¡A¥i¹LÂo¸û¤j·L¹Ð©µªøHEPA¤§¹Ø©R¡C | °¨¹F/·¨® | §l®ð°e·¦¡¡A°¨¹F¨Ã¦³¹L¼ö«OÅ@¸Ë¸m¡C | ·³t | 100¡Ó20FPM | ·Ó©ú | ¤é¥ú¿O ¶À¥ú220V | ¹q·½ | 110V 60HZ¤Î220V 60Hz ¥i¨Ñ¿ï¾Ü¡C | ¼Ð·Ç°t³Æ | 1.«ü¥Ü¿O 2.p®É¾¹ 3.´¡®y 4.HEPA¶ì½¦«OÅ@ºô 5.À£®tp | ¡@««ª½¦¡¤u°µ§@Âi ³W®æ«¬¦¡ | ¥~³W¤Ø¤oW¡ÑD¡ÑH m/m | ¤u§@½d³òW¡ÑD¡ÑH m/m | HEPA Filter99.9% DOP | Pre Filter | °e·¾÷/¹qÀ£ | ·Ó©ú | | 1000¡Ñ900¡Ñ1750 | 900¡Ñ700¡Ñ750 | 24"¡Ñ36"¡Ñ3" | 16¡Ñ25¡Ñ1 | 110V220V | 20W | | 1300¡Ñ900¡Ñ1750 | 1200¡Ñ700¡Ñ750 | 24"¡Ñ48"¡Ñ3" | 16¡Ñ25¡Ñ1 | 110V220V | 30W | | 1880¡Ñ900¡Ñ1750 | 1780¡Ñ700¡Ñ750 | 24"¡Ñ72"¡Ñ3" | 16¡Ñ25¡Ñ1 | 110V220V | 40W |
CLASS100 CLEAN BOOTH ²¾°Ê¦¡¼ä²b´× ¸Ó¸Ë¸m¬O¤@ºØ³»°e°¼¶h³æ¦V¬y²b¤Æ³]³Æ¡A¥i¼sªx¥Î©ó¹q¤lºë±K»ö¾¹¡A¬ì¬ãµ¥»â°ì¡A»P¸Ë°t¦¡¼ä²b«Ç¬Û¤ñ¥¦¨ã¦³³]¸ê¤Ö¡A¨£®Ä§Ö¡A²¾°ÊÆF¬¡µ¥¯SÂI¡C
¯SÂI¡G - ±Ä¥Î¤è¿û¤ä¬[¦¡³]p¡Aµ¹¤H¥H²³æ»´¥©ªº·Pı¡C
- °t¥HÂê©w¸}½ü¡Aµ¹±z²¾°Ê©M©w¦ì´£¨Ñ·¥¤j¤è«K¡C
- ±Ä¥Î¨¾ÀR¹q³n½¤§@³òÀÉ¡A¥i¦³®Ä¨¾¤î¹Ð®J§lªþ©ó³òÅ@ªí±¡C
The device is a kind of top charging and side discharging uniflow purifying equipment. It can be widely used in electronic precision instruments, scientific research. etc. In comparison with the assembled cleaning room. It has the benefits of low investment cost, quick effect and easy movement.
Features¡G - Square steel support design gives people simple and handy feeling.
- The locking casters provide great convenience of movement and fixing.
- Static electricity resistant diaphragm can serve as a fender to prevent the dust from attaching onto the surface of the product effectively.
«¬¸¹ | ²¾°Ê¦¡¼ä²b´× | ¼ä²b«× | 100¯Å@ 0.5£gm | ¥~«¬¤Ø¤o | 2000W¡Ñ1600D¡Ñ2450H¡]mm¡^ | °ª®Ä²v¹LÂo¾¹³W®æ | 1170¡Ñ570¡Ñ75¡Ñ2 | ·Ó©ú | 30W¡Ñ1 | ¹q·½ | 220V/60Hz | «¶q | 300kg |
CLASS100 CLEAN BOOTH ²¾°Ê¦¡¼ä²b´× ¤Ø¤o«¬¸¹ | ¥~³¡¤Ø¤oW¡ÑD¡ÑH | ¤º³¡¤Ø¤oW¡ÑD¡ÑH | FFU¹qÀ£ | HEPA | CB-12719 | 1200mm¡Ñ700mm¡Ñ2300mm | 1200mm¡Ñ700mm¡Ñ1900mm | 1£r220¡Ñ1 | 22"¡Ñ34"¡Ñ3" | CB-18719 | 1800mm¡Ñ700mm¡Ñ2300mm | 1800mm¡Ñ700mm¡Ñ1900mm | 1£r220¡Ñ1 | 22"¡Ñ46"¡Ñ3" | CB-30719 | 3000mm¡Ñ700mm¡Ñ2300mm | 3000mm¡Ñ700mm¡Ñ1900mm | 1£r220¡Ñ2 | 22"¡Ñ46"¡Ñ3"¡Ñ2 |
¹j¶zªùªº¦¡¼Ë ¹Ï°O¸¹ | ¤º®e | D | ³æ¶} | W.D | ³æ¶}¡]¶}µ¡¡^ | DOD-1 | ¤l¥Àªù | WOD-1 | ¤l¥Àªù¡]¶}µ¡¡^ | DOD-2 | Âù¶}ªù | WOD-2 | Âù¶}ªù¡]¶}µ¡¡^ | AD | ¦Û°Êªù | AWD | ¦Û°Êªù¡]¶}µ¡¡^ |
®ð±Kªù»P®ð±Kµ¡-¬I¤u½d¨Ò
|